Atomizer Special Atomizer for Hypochlorous Acid water (Max 50ppm) High Durability. Dry Fog. Spread Fast. VC-JM-200 VC-JM-301 VC-JM-1000 Wall –Hangable ViruClear Atomizer , Standard compact type model. Model: VC-JM-200 Nominal oscillation frequency: 2.4MHz(Ultrasonic transducer is made in Japan) Power input: DC24V(Attached adaptor) Power consumption: under 15W Capability of atomization: approx. 125cc/an hour Central atomized particle size: approx. 3μm Operation mode: Continuous mode/Intermittent mode 1/Intermittent mode 2 ※mode 1: 1 minute atomize and stop 3 minutes ※mode 2: 1 minute atomize and stop 9 minutes Bottle capacity: 1000ml Atomization level: 1/1, 1/2, 1/4 Ambient temperture:5℃~35℃ External dimensions: L 180×W 100×H 180mm(excluding bottle) Weight: Main unit: 650g (excluding solution), AC adaptor: approx. 120g Cord length:1.8m Accessories: AC adaptor, Bottle (1000ml), Wall-hang fitting (Mounting screw×2) Other equipment: Water exhaustion lamp, Corresponded hypochlorous acid water (Under 50ppm) Hypochlorous acid water Usable under 50ppm 125ml/h Use of wall hanging How to use VC-TM-200 Principle and Usage of ViruClear Atomizer. Scatter the Solution with energy of Ultrasonic Set ultrasonic transducer facing to the surface of liquid. When the ultrasonic oscillate forcibly , wave rise at center of high sound pressure, and energy of ultrasonic centralize and make water column. At this moment, surface wave is occurring on water column’s surface. This surface’s standing wave is called capillary wave which is a fine wave. From this wave’s edge (wave crest), droplet scatter as a mist. This is a principle of mist generation. Atomizer and make relaxation space by mist effect. Model: VC-JM-301 Nominal oscillation frequency: 2.4MHz(Ultrasonic transducer is made in Japan) Power input: DC24V(Attached adaptor) Power consumption: under 15W Capability of atomization: approx. 125cc/an hour Central atomized particle size: approx. 3μm Operation mode: Continuous mode/Intermittent mode 1/Intermittent mode 2 ※mode 1: 1 minute atomize and stop 3 minutes ※mode 2: 1 minute atomize and stop 9 minutes Bottle capacity: 1000ml Atomization level: 1/1, 1/2, 1/4 Ambient temperture:5℃~ 35℃ External dimensions: L 180×W 100×H 180mm(excluding bottle) Weight: Main unit: 650g (excluding solution), AC adaptor: approx. 120g Cord length:1.8m Accessories: AC adaptor, Bottle (1000ml), Wall-hang fitting (Mounting screw×2) Other equipment: Water exhaustion lamp, Corresponded hypochlorous acid water (Under 50ppm) Hypochlorous acid water Usable under 50ppm 300ml/h Reception Hall Reception Room Adjust volume of atomization for each space and situation. Model: VC-JM-1000 Nominal oscillation frequency: 2.4MHz(Ultrasonic transducer is made in Japan) Power input: DC24V(Attached adaptor) Power consumption: under 15W Capability of atomization: approx. 125cc/an hour Central atomized particle size: approx. 3μm Operation mode: Continuous mode/Intermittent mode 1/Intermittent mode 2 ※mode 1: 1 minute atomize and stop 3 minutes ※mode 2: 1 minute atomize and stop 9 minutes Bottle capacity: 1000ml Atomization level: 1/1, 1/2, 1/4 Ambient temperture:5℃~ 35℃ External dimensions: L 180×W 100×H 180mm(excluding bottle) Weight: Main unit: 650g (excluding solution), AC adaptor: approx. 120g Cord length:1.8m Accessories: AC adaptor, Bottle (1000ml), Wall-hang fitting (Mounting screw×2) Other equipment: Water exhaustion lamp, Corresponded hypochlorous acid water (Under 50ppm) Oscillation frequency: 2.4MHz(Ultrasonic transducer is made in japan) Power input: DC24V(Please use attached adaptor) Power consumption: 70VA Capability of atomization: approx. 1000ml(Continuous mode in water temperature 25℃) Central atomized particle size: 3μm or less Operation mode: Continuous mode/Intermittent mode 1/Intermittent mode 2/Intermittent mode 3 Intermittent mode 1: 1 minute atomize and stop 1 minutes Intermittent mode 2: 1 minute atomize and stop 3 minutes Intermittent mode 3: 1 minute atomize and stop 9 minutes Bottle capacity: 3300ml Ambient temperture:5℃~35℃ (No condensation permitted) External dimensions: L 334 mm ×W 230 mm ×H 310 mm (Excluding duct size) Duct size: φ60 mm ×400 mm Weight: Main unit: 6.8 kg (Excluding solution) Cord length: Power cord: 2 m Accessories: AC adaptor, Normal duct, Bottle (3300ml) Other equipment: Water exhaustion lamp, Wind volume adjust switch Hypochlorous acid water Usable under 50ppm 1000ml/h *When the water temperature is low, the quantity of atomization will get low by bubble sticking to transducer side. When the water temperature is high, the quantity of atomization will be a lot. *Please clean with cotton swab periodically, because when the surface of vibrating side gets dirty, or bubble stick on it, the quantity of atomization will get low. *Due to mist flows backward by making duct longer or shoter, Please talk to us before you do. *Unable to use Aroma liquid and Chlorine dioxide solution for ViruClear. Hypochlorous acid water concentration of 50ppm (There are solutions which could not use depends on pH value)